FUKUDA

Gross Leak Test

Gross Leak Test System
MSZ-6200 series

This is a dedicated device for gross leak test. Measurement of up to 7200 units per hour is possible.

Basic specification
Test piece size(mm) 1.6×1.2~3.2×2.5
Process Capacity 12ch 0.5s/part, 1.0s/part
Judgment Level(Pa・m3/s) Gross Leak: 2×10-7〜Large Leak
(Equivalent standard leak)
Power Source/Applied Current AC100V±10% Single-phase 50/60Hz1.5kVA
External Dimensions
(Unit: mm)
W1000×D1000×H1800
*signaltower excluded
Download
YouTube Video
Gross Leak Test System
MS-6086 series

This is a dedicated device for gross leak test.

Basic specification
Test piece size(mm) 1.6×1.2~2.5×2.0
Process Capacity 8ch 1.0s/part
Judgment Level(Pa・m3/s) Gross Leak:2×10-7〜Large Leak
(Equivalent standard leak)
Power Source/Applied Current AC100V±10% Single-phase 50/60Hz 1.5kVA
External Dimensions
(Unit: mm)
W1020×D985×H1450
*signaltower excluded
Download
Gross Leak Test System
MS-512 / 522 series

This airtight testing system is designed for use in small volume tests such as of devices under development, in preliminary experiments before introduction to mass production lines, and in sampling tests.
Target test size:2.5×2.0mm ~up to φ18.5 ×length 30mm

Basic specification
Judgment Level(Pa・m3/s)

▼Under test pressure of 200kPa

FL-510:
1 ×10-4~Large leak
Large test pieces
(up to φ18.5 ×length 30mm)
*MS-511 only
FL-513:
1 ×10-5~Large leak
5.0×3.2mm
FL-515:
5 ×10-6~Large leak
2.5×2.0、3.2×2.5mm
Channels MS-512: 1ch
MS-522: 2ch
Power Source AC100V±10% Single-phase 50/60Hz
External Dimensions (Unit: mm) MS-512: W300×D510×H368
MS-522: W384×D510×H368
Download

Request for Estimate/Demo test/Repair. Please feel free to ask me.