FUKUDA

Bombing /Gross /Fine Leak Test

Bombing/Gross/Fine Leak Test System
MSX-7000 series

This system can control bombing conditions (Helium charge), gross leak tests, and fine leak tests. Industry's first model which is compatible with 1.0 x 0.8 size. Conveyance accuracy is improved through position correction which uses image processing.

Basic specification
Test piece size(mm) 1.0×0.8、1.2×1.0
Process Capacity 12ch 1.0s/part Bombing : 60min
Judgment Level(Pa・m3/s) Gross Leak:8×10-8~Gross Leak
(Equivalent standard leak)
Fine Leak:1×10-9〜(He)
Power Source/Applied Current AC200V±10% Three-phase 50/60Hz 4kVA
External Dimensions
(Unit: mm)
W1800×D1400×H1800
*Signal Tower excluded
Download
YouTube Video
Bombing/Gross/Fine Leak Test System
MSX-6200 series

This fully-automatic system conducts leak testing while controlling the bombing (Helium charge), gross leak test, and fine leak test conditions.

Basic specification
Test piece size(mm) 2.0×1.6~3.2×2.5
Process Capacity 12ch 0.8s/part Bombing : 60min
Judgment Level(Pa・m3/s) Gross Leak:2×10-7~Large Leak
(Equivalent standard leak)
Fine Leak:1×10-9~(He)
Power Source/Applied Current AC200V±10% Three-phase 50/60Hz 4kVA
External Dimensions
(Unit: mm)
W1600×D1000×H1800
*signaltower excluded
Download
YouTube Video
Bombing/Gross/Fine Leak Test System
MSX-6110 series

This fully-automatic system conducts leak testing while controlling the bombing (Helium charge), gross leak test, and fine leak test conditions.

Basic specification
Test piece size(mm) 1.2×1.0~2.0×1.6
Process Capacity 8ch
1.2s/part Bombing: 60min
1.0s/part Bombing: 40min
Judgment Level(Pa・m3/s) Gross Leak: 2×10-7〜Large Leak
(Equivalent standard leak)
Fine Leak:1×10-9〜(He)
Power Source/Applied Current AC200V±10% Three-phase 50/60Hz 4kVA
External Dimensions
(Unit:mm)
W1800×D1150×H1800
*signaltower excluded
Download
YouTube Video
Bombing/Gross/Fine Leak Test System
MSX-0101 series

This leak test system is designed for small volume tests such as of devices under development and sampling tests. This system can control bombing conditions (Helium charge), gross leak tests, and fine leak tests.

Basic specification
Test piece size(mm) 1.2×1.0~2.5×2.0
Φ12~3.2×2.5
*The applicable testing size varies depending on the gross leak sensor model.
Judgment Level(Pa・m3/s) Gross Leak:2×10-7~Large Leak
(Equivalent standard leak)
Fine Leak:1×10-9~(He)
Power Source/Applied Current AC100V±10% Single-phase 50/60Hz 2kVA
External Dimensions
(Unit:mm)
W1000×D850×H1200
Download

Request for Estimate/Demo test/Repair. Please feel free to ask me.